Piper PA34-200T Seneca II: Difference between revisions
Jump to navigation
Jump to search
→Power Plant Limitations
Line 190: | Line 190: | ||
|} | |} | ||
=== Power | === Power Plant Limitations === | ||
{| width="100%" | |||
| width="50%" | Maximum Rotational Speed | |||
| width="50%" | 2575 | |||
|- | |||
| Maximum Manifold Pressure (Inches of Mercury) | |||
| 40 | |||
|- | |||
| Maximum Cylinder Head Temperature | |||
| 460 °F | |||
|- | |||
| Maximum Oil Temperature | |||
| 240 °F | |||
|- | |||
| Minimum Oil Pressure (red line) | |||
| 10 PSI | |||
|- | |||
| Maximum Oil Pressure (red line) | |||
| 100 PSI | |||
|- | |||
| colspan="2" align="center" | | |||
<b>NOTES</b> | |||
Avoid continuous operation between 2000 and 2000 RPM above 32 IN. HG. manifold pressure. | |||
Avoid continuous ground operation between 1700 and 2100 RPM in cross and tail winds over 10 knots. | |||
|} | |||
=== Power Plant Instrument Markings === | === Power Plant Instrument Markings === |