The output property /systems/static[n]/pressure-inhg is filtered. Therefore, if you want to see the effect of the measurement failure, "tau" should be 0.1 or smaller. | The output property /systems/static[n]/pressure-inhg is filtered. Therefore, if you want to see the effect of the measurement failure, "tau" should be 0.1 or smaller. | ||
The "error-factor" should be between 0.2 and 0.7. Setting it to 0 equals a "perfect sensor". A setting of 1 means the whole (projected on static port face) impact pressure is applied. This is not realistic as usually there are more than one static pick-up points and so the pressure increase gets "flattened". | The "error-factor" should be between 0.2 and 0.7. Setting it to 0 equals a "perfect sensor". A setting of 1 means the whole (projected on static port face) impact pressure is applied. This is not realistic as usually there are more than one static pick-up points and so the pressure increase gets "flattened". | ||
The "tau" parameter controls the responsiveness of the filter that is applied after the calculation of the new values (responsiveness = dt/tau). | |||